Get a Quote

Ai UL/CSA SolventVap 1.3G/5L Rotary Evaporator w/ -22F ...

1 set. ULVAC 220V 1.6 cfm 7.5 torr 2-stage PTFE diaphragm pump fitting. 1 set. Ai 220V SolventVap 1.3-gallon rotary evaporator and water bath. 1 set. Vertical condenser with 2 chilling water ports and 1 vacuum port, glass. 1 pc. 1.32G/5L round …

10L Short Path Distillation Kit - Rotovap

10l short path distillation kit pdf. Category: short path distillation kit for sale. Telephone. +86-371-67447999. Email. [email protected] Whatsapp. +86-13783661974.

Ice Build Up On Rotovap Trap -

14. Ensure that there is solid dry ice visible in the trap at all times. Operation 1. Fit your sample to a bump trap of the appropriate size and attach with a keck clip 2. Attach sample-trap apparatus to the rotary unit, and secure to the rotary unit with the metal clip. 3. Turn on the power switch, on the right hand side of the water bath. Get ...

Wilmad LG-6881-116 Borosilicate Glass RotoVap Trap Two 3 ...

24/40 Lower Standard Taper Joint: Industrial Scientific,Wilmad LG-6881-116 Borosilicate Glass RotoVap Trap, Two 3 mm Holes, 500 mL Capacity, 24/40 Upper Standard Taper Joint,Affordable goods,best prices, best service,Authentic Merchandise,New goods listing,Quality Products at Discount Prices.

How to use a Rotary Evaporator - University of California ...

Apr 01, 2010 The flask with the solution is placed on the rotary evaporator. The use of a bump trap prevents the solution from accidentally splashing into the condenser (and being contaminated). It is highly advisable to start with a clean bump bulb in case something bumps over after all! This would allow the experimenter to recover the solution or solid. 3.

A gentle warning about upper entrances - Honey Bee Suite

Aug 31, 2016 X 2 inches). About triple the size from when I bought it. I have the entrance on the bottom side of the inner cover. Also use an imirie shim on top of the inner cover with a the same size notch on the bottom of the shim. For my bottom entrance I use an entrance reducer with the opening being 3/8ths by 7 inches.

Evaporators - Buchi R-114

Buchi R-114 Rotary Evaporator Rotovap w/B-480 Bath Working Great. $. 889.00. Buy It Now. Free Shipping. Condition: Used. Location: Columbus, United States. R-114 Rotovap Base. This rotovap is partnered with a 5 Liter B-480 water bath with …

Chemglass Life Sciences Bump Trap 250mL Rotary ...

Bump Trap, 250mL, Rotary Evaporator, 24/40 Top Outer, 24/40 Lower Inner. Used between the vapor tube and evaporation flask on a rotary evaporator to prevent contents of the flask from being drawn into the condenser in the event of “bumping.” Traps have a 24/40 top outer joint and the listed size of lower inner joint.

How Rotovap Bump Trap -

Bump Trap, 500mL, Rotary Evaporator, Modified, 24/40 Top Outer, 24/40 Lower Inner. Similar to CG-1320, but with the addition of two 4mm drain holes at the base of the inner tube to allow solvent to drain back into the evaporation flask. Traps have a 24/40 top outer joint and the listed size of lower inner joint. Encompass Procurement Services.

Simple Honeybee Swarm Trap : 11 Steps (with Pictures ...

Cut the top to 12 X 15 for the 5.5 gallon trap. (See step 11 for size options.) Any wood or light, hard, waterproof material will do, but thin plywood works nicely. It will keep the trap light in weight for easy handling. Invert and center the trap onto the underside of the top and mark where the three 1/4 holes you drilled earlier are.

Roto Clamp for USA Lab Rotovap - Various Sizes - USA Lab

Inner Diameter of Clamp. 25mm. 40mm. 50mm. 70mm. Outer Diameter of Clamp. 60mm. 70mm. 80mm. 110mm. Corresponding PTFE Seal Washer Size. 35. 50. 60. 80 . For Technical Support, Questions, or Other Issues Please Email or Call Us! Model: RotoClamp MPN: ROTOClamp ... Rotovap Feed Tube for USA Lab Rotary Evaporators RE series - 1005, 1020, 1050 ...

Waste water traps - the different types explained

Like the 'P' trap, the 'S' also requires a fair amount of room around the waste outlet. The 'Bottle' trap, access to clean the trap is by unscrewing the bottom. The waste pipe is always fitted horizontally. The 'Bottle' trap takes up less space under a waste outlet and is ideal for pedestal mounted basins where space is usually very limited.

Falling Film vs. Rotovaps: the fracTron solution - extraktLAB

Mar 10, 2020 A thin film improves mass transfer and speeds evaporation while a vacuum is used to decrease the boiling point of the target solvent. The key difference between a rotovap and a thin film is in how that film is created and how much throughput can be produced. In the case of a falling film evaporator there is a series of vertical bundles of metal ...

What is a bump trap? -

May 11, 2020 Bump Traps. Chemglass. Used between the vapor tube and evaporation flask on a rotary evaporator to prevent contents of the flask from being drawn into the condenser in the event of “bumping.”. Traps have a 24/40 top outer joint and the listed size of lower inner joint. Find out everything you need to know about it here.

Rotary Evaporator Bump Traps - Safety Emporium

Product Description. These are the most traditional rotary evaporator bump bulbs/traps which are used between the vapor tube and evaporation flask on a rotary evaporator to prevent the contents of the flask from being drawn into the condenser in the event of solvent bumping. The lower stem has 2 large holes; see CG-1321 and CG-1322 for modified ...

Rotary Evaporator Cost For Leasing Financing in 2022

Rotary evaporation is accomplished using a rotary evaporator, also known as a rotovap or rotavap. It is a commonly used technique for separating a compound of interest from a low-boiling solvent, such as an organic, inorganic, or polymeric substance. Separation is accomplished by heating a mixture of solvent and compounds inside an evaporation ...

Rotary Evaporator Trap at Thomas Scientific

Rotary Evaporator Bump Traps, Modified Chemglass Trap provides expanded volume for reactions that have a tendency to foam excessively. The inner vapor tube is sealed to the top of the trap to prevent entry into the condenser. Traps have a 24/40 top outer joint and the listed size of lower inner joint. Related Products: Rotary Evaporator Bump Traps

Rotary Evaporator Bump Traps Chemglass VWR

Rotary evaporators featuring bump trap.Placing vacuum traps between an apparatus and vacuum source establishes a safe and controlled working system. The glassware protects the pump from the separated solvents while simultaneously preventing vapors from being emitted back into the system. Vacuum traps in reservoir, one piece, or two piece styles also guarantee …

Rotary Traps Fisher Scientific

Stopper has a standard taper inner joint and body has an outer joint. Body length is the overall length from the top of the joint to the bottom of the round bottom. Serrated hose connections have an O.D. of 13mm at the smallest serration and 16mm at the largest serration. 21

Factors Affecting the Distillation Efficiency of Lab Rotovap

Temperature of the Heating Pot. The higher the temperature of the laboratory rotary evaporator, the faster the distillation of the solvent. Considering the safety of the operation and the heat sensitivity of the target component, the most common temperature is 60 C or 80 C or more, but the silicone oil medium is difficult to clean.

R-1020 Double Cold Trap Rotary Evaporator - Rotovap

The maximum capacity of a R-1020 double cold trap rotary evaporator is 2000ml, the rotating speed is from 5rpm to 120rpm, and the motor power is 60W. It adopts fully automatic control of temperature, rotating speed and bath’s lifting. The rotary evaporator can rotate to form a thin film and evaporate efficiently under the constant temperature ...

Vacuum Rotovap Rotary Evaporator ... - Careddi Supercritical

The pressure inside evaporator won't be changed during draining. 9. Digital display of temperature and rotation speed 10. Heavy-duty SS304 support frame and epoxy-coated water/bath enclosure guarantees vibration-free operation. 11. Various options and accessories are available (vacuum pump, chiller, vacuum controller, cold trap, etc) 12. One ...

Rotary Evaporator Bump Traps Fritted Disc

These bump traps have an extra coarse fritted disc sealed between the lower inner and top outer joint to prevent the contents of the flask from bumping into the condenser. This is a convenient, space-saving design good for cramped dry boxes, for example. The top outer joint is a 24/40 standard taper. The bottom standard taper inner joint is available in 14/20, 24/40 or 29/42 sizes.

Rotary Evaporator Replacement Glassware

trap body with a 35/20 inner ball joint bottom connection that attaches to the receiver flasks (which are sold separately). Features standard top and side flange that connects directly to the Buchi rotary evaporator. Assembly “C” also includes the glass cold trap inner body, Buchi Part #00672, PTFE sealing ring with Viton O-Rings, PTFE lid or

10l rotovap - Lab Instrument Manufacturer

Turn on heat bath and set to 40C (113F). Once heat bath, chiller and cold trap have reached desired temperatures, turn on rotovap motor and set speed to approximately 100 RPM (does not have to be precise). Keep in mind, higher RPM’s will increase evaporation power but also increase heat load.

Contact Us
advanced technology

High-tech Zone, Zhengzhou, China

Inquiry Online
Related Post
Leave Us Message
customer service img

We immediately communicate with you

Get Quote Online

If you have any needs or questions, please click on the consultation or leave a message, we will reply to you as soon as we receive it!

<script type="text/javascript" src="https://s9.cnzz.com/z_stat.php?id=1281096741&web_id=1281096741"></script>