Get a Quote

(PDF) Antibacterial activity of iron oxide iron nitride ...

Antibacterial activity of iron oxide, iron nitride, and tobramycin conjugated nanoparticles against Pseudomonas aeruginosa biofilms

A Glove Box Lesson from A to Z - Inert Corp

Apr 03, 2017 A to Z. Acrylic Glove Box: This phrasing is common for lower-end, bench-top glove box models with a purge-style release that do not typically include a gas management system. Rather, inert gas is constantly pumped into and purged from the enclosure to maintain low O 2 and H 2 O levels. These are more common among less sensitive applications.

The Glassware Gallery: Schlenk Lines and Vacuum Lines

Aug 29, 2020 Vacuum lines usually have a better vacuum (10 -4 to 10 -7 torr) than Schlenk lines (10 -2 to 10 -4 torr), because vacuum lines typically have a diffusion pump. A way of delineating these would be to use the terms Schlenk line and High vacuum line. Vacuum lines usually connect to the experimental apparatus with joints, which provide a better ...

VWR Part of Avantor - Chemicals and Laboratory Scientific ...

Avantor , a Fortune 500 company, is a leading global provider of mission-critical products and services to customers in the biopharma, healthcare, education government, and advanced technologies applied materials industries.Our portfolio is used in virtually every stage of the most important research, development and production activities in the industries we serve.

PowerPoint Presentation

Changing Vacuum Pump Oil. Ensure that the pump is off. Use screwdriver to remove the hose from the pump to the manifold. Place pump on bench top. Find an empty container for pump oil waste. Attach a latex or tygon tube to the drainage nozzle and open to allow the oil to flow out. Tilt the pump to drain the remaining oil.

Standard Operating Procedure: Pumps middot; PDF ...

Feb 06, 2018 Belt drive pumps are located underneath the hoods and are primarily used for Schlenk Line work (Schlenk Line usage detailed in Schlenk Line SOP document). A belt drive pump is also located underneath the Rotovap station and details of its use can be found in the Rotovap SOP, but general maintenance information can be found in this SOP document.

The General Use of Gloveboxes - Labideal

Feb 08, 2020 The glove box functions by containing a shut blood flow loop which utilizes aundefinedblower and plumbing related, along with a purifier to maintain H2O and O2 levels lower than 1 ppm. The atmosphere is purified by air circulation via a catalyst bed to eliminate moisture and O2. The catalysts consist of copper based contaminants to eliminate O2 and molecular …

Antibacterial activity of iron oxide iron nitride and ...

Feb 18, 2020 The NPs were synthesized using a solvothermal method on a Schlenk line under inert gas flow. After synthesis, the NPs were capped with natural alginate and half of the batch was crosslinked to tobramycin using 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride (EDC, also abbreviated as EDAC or EDIC)/N-hydroxysulfosuccinimide (sulfo-NHS ...

Freeze-Pump-Thaw - The Schlenk Line Survival Guide

Freezing in liquid nitrogen. Step 3 – Pump: Once the contents of the Schlenk flask have frozen, open the stopcock to evacuate the headspace. Keep under vacuum for 3-5 minutes whilst submerged in liquid nitrogen. Evacuating the headspace. Step 4 – Thaw: Close the stopcock to seal the flask under vacuum and remove from the dewar of liquid ...

Glovebox Technique - an overview ScienceDirect Topics

In a glove box, 15 mL of toluene, 1.736 g (21 mmol) of 1-hexene were mixed together in a 100 mL two-necked round-bottom glass flask with a stirring bar. The flask was taken outside and attached to a Schlenk line, a well-purged ethylene line, and a mercury-sealed stopper.

Gloveboxes - The Schlenk Line Survival Guide

It is recommended to have three 5 minute cycles for the small antechamber, and three 15-20 minute cycles for the large antechamber. The latter can be automated for some glovebox models. Glassware, including vials and pipettes, introduced into the glovebox should be dried in an oven prior to use. Cycling items into the glovebox using the small ...

Supporting Information General

Jan 25, 2007 The Schlenk flask was removed from the glove box and degassed with three freeze-pump-thaw cycles on a vacuum line. Using a known volume bulb attached to the vacuum line, a known amount of PMe 3 (0.54 mmol) was condensed into the flask at -196 C. The solution immediately turned orange and was stirred for 1 hour. The flask was brought into the ...

76 questions with answers in HIGH VACUUM Science topic

Mar 09, 2022 6 answers. Feb 6, 2019. I use two pumps to attain a high vacuum environment. Firstly, I connect only gauge with turbo pump and diaphragm pump to check two pumps. After I start two pumps ...

Tips and Tricks for the Lab: Air-Sensitive Techniques (1 ...

May 07, 2013 The design of Schlenk lines varies from line to line, from lab to lab. There are, however, several key features that a Schlenk line will include (Figs. 1 and 2): Dual manifold. Inert gas inlet. Inert gas outlet via a bubbler. Vacuum pump. One or more cold traps for solvents. Taps to switch between gas and vacuum.

Mechanochemistry allows carrying out sensitive ...

May 07, 2019 This study thus illustrates the outstanding potential of mechanochemistry to serve as an operationally simple, glove-box-and-Schlenk-line-free synthetic route to organometallic compounds and other valuable synthetic targets, even when sensitive reagents or intermediates are involved. PMCID: PMC6566379 PMID: 31293773

Welcome to the Rodriguez Group!

MBraun glove box used as dry box. Refurbished VAC glovebox used as wet box. Vacuum line (~1 mTorr) for fast sealing of ampoules. Oxygen torch for sealing ampoules for solid state reactions. Schlenk line with trap and vacuum system consisting of an all-glass diffusion pump attached to an Edwards rotary vane pump. Mellen 1200 C large volume box ...

Mechanochemistry allows carrying out sensitive ...

Mechanochemistry allows carrying out sensitive organometallic reactions in air: glove-box-and-Schlenk-line-free synthesis of oxidative addition

Schlenk Techniques PDF Filtration Laboratories

Methods of Degassing. • Freeze-Pump-Thaw. This is the most effective methods for solvent degassing. A solvent in a sealed Schlenk or. heavy wall sealed tube is frozen by immersion of the flask in liquid N 2. When the solvent is. completely frozen, the flask is opened to the vacuum (high vacuum) and pumped 2-3.

0DWHULDO (6 IRUKHPRPP 7KLV

mL Schlenk flask and transferred into a nitrogen filled glove box. 100 to 150 mL of pentane was added to the flask to dissolve the acid. The flask was sealed with a septum and was transferred onto a Schlenk line. In the nitrogen filled glove box, 2.25 grams (18.2 mmol) of diethyl zinc was

Scilit Article - A Glove-Box- and Schlenk-Line-Free ...

Oct 16, 2020 A Glove-Box- and Schlenk-Line-Free Protocol for Solid-State C–N Cross-Coupling Reactions Using Mechanochemistry. Koji Kubota, Rikuro Takahashi, Minami Uesugi, Hajime Ito. Published: 16 October 2020. by American Chemical Society (ACS) in ACS Sustainable Chemistry Engineering.

Standard Operating Procedure: Pumps

Oct 31, 2016 Belt drive pumps are located underneath the hoods and are primarily used for Schlenk Line work (Schlenk Line usage detailed in Schlenk Line SOP document). A belt drive pump is also located underneath the Rotovap station and details of its use can be found in the Rotovap SOP, but general maintenance information can be found in this SOP document.

SOP-Pumps_20161031 Vacuum Pump

Oct 31, 2016 Direct Drive Pumps Direct drive pumps are located underneath the glove boxes and used for evacuating the glove box ports. ... (Schlenk Line usage detailed in Schlenk Line SOP document). A belt drive pump is also located underneath the Rotovap station and details of its use can be found in the Rotovap SOP, ...

Operating procedure of Schlenk line (for mixing two ...

pump. (Fig. 3)Liq N2 should be used in the cold trap while evaporating solvents] 3. Oleic acid (39 ml) taken in a beaker is syringed out and injected in the flask through the septum. Heated and cooled as described in procedure. 4. Titanium isopropoxide taken in a small Schlenk flask or tube fitted with a septum inside glove box and then taken ...

View Article Online Chemical Science

reactions in air: Glove-box-and-Schlenk-line-free synthesis of oxidative addition complexes from aryl halides and palladium(0) Koji Kubota,*a,b Rina Takahashi,a and Hajime Ito*a,b

Schlenk Lines and Vacuum Lines - Louisiana Tech University

Schlenk Lines and Vacuum Lines Introduction. Schlenk lines and vacuum lines provide a convenient means of manipulating air and water-sensitive materials without the use of an inert atmosphere glove box.There is no strict definition that divides the term Schlenk line from vacuum line, chemical transfer line or vacuum transfer line, but in some general …

Standard Operating Procedures: Bart Laboratory

Using Schlenk Line 10-14 Solvent Purification System 15-16 Using Rotovap 17-18 Preparation of UI 3 19-20 Preparation of UCl 4 21-22 ... In order to remove solvent from the reactions performed inside of the glove box, a vacuum pump is attached from behind the glovebox. In order to prevent both solvent from getting into

Bartlett Group SOPs 2017

work involving oxidizing chemicals must be conducted in a fume hood, glove box, or isolated in an acceptable manner. 4. Mechanical vacuum pumps must be protected using cold traps and, where appropriate, filtered to prevent particulate release. The exhaust for the pumps must be vented into an exhaust hood. Decontamination procedures

Contact Us
advanced technology

High-tech Zone, Zhengzhou, China

Inquiry Online
Related Post
Leave Us Message
customer service img

We immediately communicate with you

Get Quote Online

If you have any needs or questions, please click on the consultation or leave a message, we will reply to you as soon as we receive it!

<script type="text/javascript" src="https://s9.cnzz.com/z_stat.php?id=1281096741&web_id=1281096741"></script>